DISTAX_300A
Full Automation of Machine Tool Accuracy Inspection.
Feature
Specifications
Model | 3 0 0 A |
---|---|
Maximum measuring range | Corner cube: 10 m, Plane mirror: 5m |
Optical fiber length | 3 m, 5 m, 10 m standard |
Resolution | Corner cube: 5nm, Plane mirror: 2.5nm |
Maximum response speed | Corner cube: 630mm/s(Special order: 1000 mm/s) Plane mirror: 315mm/s |
Accuracy | ±(Lx10-7+0.01×10-6)m L=measuring length(m) |
Number of axes | 2 max. |
Laser Head | |
Light source | Stabilized wavelength single mode He-Ne laser |
Light output | Approximately 0.3W (per axis) |
Wavelength stability | ±1×10-7 |
Number of optical axes | 3 max. |
Warm-up time | Approximately 10 minutes |
Input voltage (PS-300A power supply for laser head) |
Single phase AC 100V ±10% |
Frequency 50/60Hz | |
3-pint AC plug | |
Power consumption | 90 VA |
Dimensions and weight | 160(W)x455(D)x116(H)mm 7.5kg |
Usage environment | Temperature: 10°C to 40°C (±10C temperature variation during operation) Humidity: 10 to 90% (no condensation) |
Counter Board | |
Maximum response frequency | 2.0MHz |
Reflection mirror movement speed |
Single path interference head: Approximately 630 mm/s (when basic resolution = λ/2 ) |
Plane mirror interference head: Approximately 315mm/s (when basic resolution = λ/4 ) | |
Maximum count | ±233-1 |
Data output delay time | max.1μs |
Number of axes | 1 axis/1 board |
DISTAX Manager Software | |
Number of measurement points | Up to 3 axes, measured sequentially |
Connection to NC Unit | RS-232C |
Types of NC units | FANUC 16, 18, 21 MELDUS 64 |
Measurement/ output content |
Full compliance with ISO 230-2 (1988, 1997) Various positioning accuracy inspection items, including average reversing error Various graph outputs Formatted inspection report output |
Correction | Pitch error and backlash error. (Automatic correction) |
Functions required by NC controller |
Programmable parameters (required for automatic correction) Tape operation mode (required for automatic operation of NC from a PC using G-codes) (If this mode is not available, the NC can operate in the memory mode and automatic measurement can be performed using data from the DISTAX counter.) |