Best suitable for auto measurement for DCR of tip inductor/ fuse resistance value
● Measuring range:
[% Measurement] 1mΩ~9.99mΩ/±50.0%
10mΩ~10kΩ/±50.00%
[mΩ measurement] 0.00mΩ~15.000kΩ%
● Measurement not to influenced by thermal electro motive force.
● Available to measure without error by relay time setup each range
● Circuit designed to eliminate contact error as much as possible
● Contact-check is equipped as standard function.
● Comparison result by built-in comparator is open-collector output and displayed by LED and buzzer.
● GP-IB/RS-232C/Centoronics output available. (Option)
● Measuring current/voltage-check are built-in as standard function.
Specifications
Measuring range and Accuracy (at23℃±5℃)
Range | Measuring range | Measuring current | Accuracy [Slow] |
---|---|---|---|
100mΩ | 0.00mΩ~150.00mΩ | 100mA | within ±0.02%rdg±10μΩ ±3digit [Average] ±4digit [Slow] ±5digit [Fast] |
1Ω | 0.0000Ω~1.5000Ω | 10mA | |
10Ω | 0.000Ω~15.000Ω | 1mA | |
100Ω | 0.00Ω~150.00Ω | 1mA | |
1kΩ | 0.0Ω~1500.0Ω | 1mA | |
10kΩ | 0Ω~15000Ω | 0.1mA | |
% | 1mΩ~9.99mΩ/±50.0% | Refer to the above | |
within [(Range/Standard) /5] ×0.01%±βdigit | |||
10mΩ~10kΩ/±50.00% | within [(Range/Standard) /5] ×0.01%±αdigit |
※β:Average=1 Slow=2 Fast=3 α:Average=3 Slow=4 Fast=5
Open-circuit voltage of measuring terminal | less than 9V |
---|---|
Measuring method | 4-terminal measurement (with contact check) |
Sampling time | [Free running mode] 2~9 times per second (standard setting) |
[Remote start mode] about 18.6msec./31.1msec. (standard setting) | |
Comparator set range | [mΩ measurement] 0~15000 both the upper and lower limit. |
[% measurement] ±50.00% both the upper and lower limit. (Standard 100~999:±50.0%) |
|
Indication of comparator’s comparison result | LED indication LO/GO/HI and buzzer |
Control signal | Remote start input:”L” [0V] →”H” [DC12V] start |
Trimming signal:Open and “H” [DC12V]:Free run/”L” [0V] :Hold | |
comparison output [LO/GO/HI]:Open-collector output max.40V, 100mA | |
contact error output [CE]:Open-collector output max.40V, 100mA | |
end of comparison output [EOC]:Open-collector output max.40V, 100mA | |
Operation condition | [Temp.] +5℃~+40℃ [Humidity] less than 85% |
Power supply | AC100V/117V/220V/240V selectable, 50/60Hz, about 60VA |
Outer dimension | about 333 (W) ×99 (H) ×300 (D) mm (excluding protruding parts such as rubber legs, etc.) |
Weight | about 3.8kg |
The Outline
AX-1155B is available to measure the super-low resistance with high speed and high accuracy from 0.00mΩ to 15.000Ω(% measurement : 1mΩ~10kΩ)
In addiition, it is possible tom make the measurement the measuring object accumulately and stable, because they have DOUBLE MEASURING MODE and special AUTO-ZERO circuit that it is available to measure them after cancelation of thermoelectromotive force for error factor when the measurement is made low-resistance especially.
This checker is displayed the measured value, judged HI, GO, and LO, and then the signal is output.
The measuring speed is changeable and it is selectable AVERAGE/DOUBLE/SLOW etc.
And as CONTACT CHECK CIRCUIT and measuring current/abnormal voltage check circuit are equiped as standard, this checker become higher the confidence.
And it is available to equip the interface of GP-IB, RS-232C, or Centro Output as optional function.