Best Suitable for D, F, G, J, K classes of resistance, and coating conveyor of axial type resistor
?
● Fast measurement
(FAST:about 2.1msec. [60Hz] /2.5msec. [50Hz])
● Measuring range:0~999mΩ and 0.01Ω~99.9MΩ
● 4 Terminal Measurement less than 0~99.9kΩ,
2 Terminal Measurement (over 100kΩ)
● Available to percentage measurement by digital setup for standard resistance value
● Number of non-defective products’ digital counter is built-in
● Contact-check function is selectable from premeasurement/postmeasurement/OFF
● Shift outputs and solenoid power outputs (corresponds to DC24V)
● Standard equipments of check circuit for measuring current and abnormal voltage
Specifications
Range | Measuring range | Measuring current | Accuracy | Indication range | |
---|---|---|---|---|---|
SLOW | FAST | ||||
1Ω | 0.1Ω~0.999Ω | 200mA | within ±α±2digit | within ±β±(3+n) digit | ±9.99% |
10Ω | 1Ω~9.99Ω | 100mA | within ±0.03%±1digit | within ±0.03%±(2+n) digit | |
100Ω | 10Ω~99.9Ω | 10mA | within ±0.02%±1digit | within ±0.02%±(2+n) digit | |
1kΩ | 100Ω~999Ω | ||||
10kΩ | 1kΩ~9.99kΩ | 1mA | |||
100kΩ | 10kΩ~99.9kΩ | 100μA | |||
1MΩ | 100kΩ~999kΩ | 10μA | within ±0.1%±(2+n) digit | ||
10MΩ | 1MΩ~9.99MΩ | 1μΩ | within ±0.04%±1digit | within ±0.4%±(2+n) digit | |
100MΩ | 10MΩ~99.9MΩ | 0.1μA | within ±0.2%±2digit | ---- | ---- |
mΩ CHECK (0~999mΩ) |
100mA | within ±0.15%±1digit | within ±0.2%±2digit | 0~999mΩ |
※α:(500/setup value mΩ)×0.01%, β: (500/ setup value m Ω)×0.02%, n: when measuring time is F1, n=1, when measuring time is F2, n=0)
Measuring time | Power source frequency | Remote start | Free running | ||
---|---|---|---|---|---|
SLOW | FAST-1 (F1) | FAST-2 (F2) | SLOW | FAST | |
60Hz | about 16.7msec. |
about 2.1msec. |
about 4.2msec. |
30 times/sec. | 30 times/sec. |
50Hz | about 20.0msec. |
about 2.5msec. |
about 5msec. |
25 times/sec. | 25 times/sec. |
※Judgment time (from input start signal to output EOC signal) adds about 1.5msecond for the measuring time above (slightly differ from a range)
※When before contact check, it adds about 3.5msecond, and adds about 0.7msecond after contact-check for the judgment time above.
Open-circuit voltage of measuring terminal | less than 15V |
---|---|
Measuring method | 2 Terminal Measurement (More than 100kΩ) 4 Terminal Measurement (less than 99.9kΩ) |
Setting range for measurement value | Both upper and lower limit ±0.00%~±9.99% In a case of m Ω CHECK: 000mΩ~999mΩ |
Operation condition | [Temp.] 0℃~+50℃ [Humidity] less than 80% |
Power supply | AC100V/117V/220V/240V selectable, 50/60Hz, about 40VA |
Outer dimension | about 333 (W) ×85 (H) ×245 (D) mm (excluding protruding parts such as rubber legs, etc.) |
Weight | about 3.5kg |
The Outline
AX-175A can easily measure a wide range of resistance from 0.1Ω to 99.9MΩ, ultra fast speed, and high accuracy.
The unit is indicated the measured value as a digital and outputs signal outside to judge HI, GO, LO decision. It can be switched a measuring speed, selectable from two types of FAST, a type of SLOW.
Contact-check function as a standard equipment: When measure 4 terminals, either one contact failure occurs, judges a defect, outputs a defective signal with C.E (Contact Error) signal outside regardless of its measured value at the same time.
The behavior of contact-check is selectable from premeasurement/postmeasurement/OFF.
Besides, a checking circuit to observe an abnormal measuring current always has set, and outputs NG judgment when terminal trouble of contact condition occurred during measurement.
Shift circuit, solenoid power supply corresponds to DC24V (high speed operation can be by setup), and quality product counter are built in.