W2 Optical Emission Spectrometers
Designed Specifically for Nonferrous Metal (Arc/Spark-OES)
Ideal for nonferrous metal testing and quality control
Nonferrous metal analyzer
User-friendly software operation
Worry-free Analysis
Ultra-reliable Results
Long-term Availability
Best price/performance ratio
W2 is designed specifically for nonferrous metal. It is reliable analyzer when it comes to nonferrous metals analysis. It is our entry level model which is available as a dedicated single-base unit as well as a versatile multi-base system. The overall optical design has been enhanced, and with improvements in CCD technology used to further improve the performance of the W2 while retaining the major benefit of earlier units. This gives the W2 the ability to analysis elements across the complete range of nonferrous metals and alloys.
W2 optical emission spectrometers(spark OES) is used for applications in nonferrous metal elemental analysis for science and industry like Metallurgy, Foundry, Mechanical Engineering, Scientific Research, Product Inspection, Automobile, Petrochemical Engineering, Shipbuilding, Nonferrous Metallic Processing and Recycling. It is including full element analysis range, but at same time the element analysis amount can be bespoke.
Detection Matrices:
Aluminium(Al) and its alloys
Copper(Cu) and its alloys
Cobalt(Co) and its alloys
Magnesium(Mg) and its alloys
Zinc(Zn) and its alloys
Lead(Pb) and its alloys
Tin(Sn) and its alloys
Small sample, special size sample and wire detection
Best Long-Term Stability and Precision
1.Optical system adopts the highest-precision optical grating with the concentration of 3600l/mm, matching multiple CCD combinations, to ensure the highest precision of the optical system.
2.Innovation design of the digital excitation light source, tungsten electrode and argon gas injection excitation mode can help different excitation parameters according to the specific type of the materials, which stabilizes the spark discharge with stabilized measured results.
Spectral Lines of the Elements
1.W2 covers all the elements to be analyzed in the nonferrous metals so that customers can analyze whichever elements they need.
2.Optical system includes the solid-state detector that can measure all the spectral lines excited from the measured samples.
3.Convenient for the possible upgrade, and the addition of analysis lines(elements).
?
Control, Acquisition and Readout System
1.Electronic system has the abilities of multichannel integration controlled by microprocessors and data system acquisition.
2.High-Speed A/D Converter
3.High-Performance DSP and ARM Processors have the functions of ultra-high speed data acquisition and control.
4.The instruments can automatically monitor the real-time operation status of several modules such as the optical chamber temperature, the argon gas pressure, the light source system and operations control system.
?
Open Spark Stand
1.Open Spark Stand is free to test samples with different shapes.
2.Pollution-free Tungsten Electrodes do not need to be renewed.
3.Argon gas flushes the spark stand with low consumption of the gas.
?
Analysis Software
1.Windows-based CCD Full-Spectrum Graphical Analysis Software with Multiple National Languages is convenient and reliable.
2.The entire measurement process controlled by All-In-One Management provides users with powerful data processing and detailed test report read-out.
3.The instrument can be equipped with multiple industrial correction curves and more material analyses and advanced solutions.
4.The software realized the algorithm, with full-spectrum detection and intelligently removing interference, dark current, background and aliasing, improves the analytical ability of the instrument.
5.Complete function of automatic systematic diagnostics.
6.Complete function of database management makes it convenient to search and collect data.
7.Intelligent Correction Algorithm ensures the stability and reliability of the device.
Item | Index | |
?
?
? Optical System |
Optical Structure | Flat Field Optical |
Grating Focus | 150mm | |
Wavelength Range | 200nm-560nm | |
Detector | High resolution CCD Multi detectors | |
Spectrum Width | 18mm | |
Pixel Resolution | 30pm | |
Full spectrum | ||
Light room temperature is controlled automatically | ||
?
Spark Source |
Type | Digital arc and spark source |
Spark Frequency | 100-1000HZ | |
Plasma Current | 1-80A | |
Ignition Voltage | >7000V | |
?
Spark Stand |
Argon flushed with minimal consumption of argon | |
Spray discharge electrode technology | ||
Adjustable sample clamp | ||
?
?
? Others |
Measurable Elements | Al base |
Dimension | 520mm(L)*570(W)330mm(H) | |
Weight | About30kg | |
Storage Temperature | 0℃-45℃ | |
Operating Temperature | 10℃-35℃, 23±2℃ is recommended | |
Power | AC 220V/550Hz( can be customized if necessary) | |
Power consumption | Excitation: 600W/Stand by:50 W | |
Argon Quality | 99.999%, Argon pressure>4Mpa | |
Argon Consumption | 4L/min during spark mode |
?