Specifications
NEO-690Z | NEO-890Z | |
Max. Vol. / Max. Cur. (Max. Output) | 90kV / 0.25mA (10W) | |
Min. Focus Size | 5um | |
X-ray Camera | PONY ORIGINALDirect Conversion X-ray Camera SID-A50 | |
Geometrical Magnification (FOV in mm) | Min. GM: approx. X1.76 (29.2 X 26.4) to Max. GM: approx. X35 (1.47 X 1.32) |
|
Magnification on Monitor (Monitor Size) | approx. X9.3 to X184 (17in. with resolution of 1024 X1280) | |
Oblique View | approx. 50 deg. (Camera alone inclinates for max. magnification) | |
Geometrical Magnification during Oblique View (FOV in mm) | Min. GM: approx. X3.1 (16.6 X 15.0) to Max. GM: approx. X28 (1.83 X 1.66) |
|
Magnification on Monitor during Oblique View (Monitor Size) | approx. X16.3 to X148 (17in. with resolution of 1024 X1280) | |
Table Size | 350mm X 400mm | 510mm X 560mm |
X-Y Axis Stroke | 300mm X 350mm | 460mm X 510mm |
Z Axis Stroke | 220mm | |
Table Load Capacity | 5kg | |
External Dimensions (mm) | W930 X D1104 X H1320 | W1250 X D1424 X H1320 |
Weight | approx. 700kg | approx. 1,000kg |
X-ray Leakage (at machine surface) | less than 1uSv/hr | |
Power | AC50/60Hz 100V 15A | |
Option |
|
- System is equipped with interlock mechanism to protect the operators and engineers from unintended irradiation.
- Specifications above can be changed without prior notice.
- When the system is exported to foreign countries, Japanese Government may require exporting license.
- System specifications; including configuration, X-ray generator, X-ray camera, and shielding box may be upgraded upon request.
- PIA-Soft is a trademark of PONY INDUSTRY CO.,LTD. All other products are trademarks and registered trademarks of their respective owners.
Option
- Automatic X-ray Inspection Function
- Nowadays, more and more devices are mounted on PCB surface, like BGA and CSP. This trend is causing testable areas with AOI limited.
- Furthermore, PCB for automobile industry is under severe demand for total inspection. However, the combination of existing X-ray generator and X-ray detector cannot possibly produce stable and repeatable images. This is a fatal problem for X-ray inspection systems, and made it almost impossible to be used automatically.
- For an example, think of an AOI system; equipped with fluorescent light bulb with inverter-less power supply for the light source, and camera with terrible sensitivity and contrast degradation, which also gets images burned on easily. With such a system, no matter how incredible the software you equip it with, it would not earn the title of an “Automatic Inspection System”. This is exactly what ordinary “Automatic X-ray Inspection” on the market IS.
- This simple FACT should have been crystal clear to those who knew enough about X-rays. Nevertheless, there have been way too many inspection system manufacturers who tried creating an automatic X-ray inspection system, without considering that essential factor, and disintegrated into stars. This pitiful fact caused tremendous damage on the reputation of “X-ray Inspection Industry”, and resulted in irreparable loss of confidence from users.
- In order to resolve these issues, renewal of core devices; X-ray generator and X-ray detector is the task of pressing urgency, and we are proud to introduce them to you today.